Operating instructions
Counter and totaliser with auxiliary
functions and threshold monitoring 24
PTX800D 61001050/00/01.08
Vue de la page 0
1 2 3 4 5 6 ... 21 22

Résumé du contenu

Page 1 - PTX800D 61001050/00/01.08

deenBedienungsanleitungZähler und Totaliser mit Zusatz- funktionen und Grenzwertüberwachung 3Operating instructionsCounter and totaliser with auxilia

Page 2

32Total and rate display settings and scalingTotal decimal pointtot_dp=1234.5Introduces total decimal pointDemo, e.g., total shown to one decimal plac

Page 3 - • Operation

33General alarm settingsSetpoint securitySECure_y SECure_nSetpoints fixed at setupCan change setpointsToggle AcceptAlarm reset sequencereS_AutorES_Oper

Page 4

34InstallationCaution: In order to meet product safety requirements, these units must only be installed, by qualified staff, in accordance with the in

Page 5 - • Setup options

35Input voltages over 45 V DCIf the input voltage is above 45 V DC connect the internal high voltage select jumper before applying the signal (maximum

Page 6

36ConnectionsFor effective protection from electromagnetic noise, all signal cables must be shielded, or located on conductive trays or in conduits.St

Page 7

37PTX800 analogue output board showing output type jumper locations.Link both pairsof posts forvoltage outputsSymbolsThe instrument labels use symbols

Page 8

38NAMURsensor–PTX800D10+ 129 11For NAMUR sensornputs.NPN type3-wire sensor(O/C outputs)Sig–PTX800D9+ 10Power (+ve)SignalPower (–ve)11 12For 3-w re sen

Page 9 - • Setup Sequence

39• ModificationsAnalogue output typeThe analogue output type (current/voltage) is set by internal push fit jumper. To change the output type:Change th

Page 10 - Setup Sequence (continued)

40High/Low voltage input selection1. Gently remove the backplate (it is held in place by four lugs).2. Slide the electronics from the housing.3. Chan

Page 11

41ProcedureNote: the procedure below shows calibration for the commonly used 4-20 mA format. If you have set the outputs to any other format, the unit

Page 12 - Installation

24en PTX800DContentsOperation 25Setup options 27Setup Sequence 31Installation 34Modifications 39Output calibration 40

Page 13

42AnalogueOutputBoardLink thesepins forHigh inputvoltagesLink thesepins forNormal inputvoltagesDisplay BoardMain Board96 6 mm137 00 mmPANEL THICKNESS

Page 15 - Insulated

Weidmüller Interface GmbH & Co. KGPostfach 303032720 DetmoldKlingenbergstraße 1632758 DetmoldTel. +49 5231 14-0Fax +49 5231 14-20 83info@weidmuell

Page 16 - Input Types

25en PTX800D• OperationGeneralThe PTX800D is a scalable pulse counter/rate indicator for digital pulse signals. It will display either the rate or tot

Page 17 - • Modifications

26Viewing the alarm setpointsPress the AL1 or AL2 at any time to display the setpoint for that channel. The value will be shown for 5 s. If the alarms

Page 18 - Output calibration

27Changing the setup optionsYou should only use setup mode if you have to change a setting or calibrate the outputs. The setup mode stops all operatio

Page 19

28Input signal typeSets the input trigger and reset levels to suit the pulse source. The table below gives the threshold values.For contact closure in

Page 20 - Main Board

29Rate scaling factorThe rate scaling factor sets the ratio between the total display and the rate display. It must be a power of ten (i.e., 1000, 100

Page 21

30Alarm actionHigh alarms are active above the setpoint and low alarms are active below the setpoint. Total alarms are always ‘high’ type, so this set

Page 22

31Analogue output formatThese setup parameters let the PTX800D show the output range correctly during review mode and prompt for the correct values du