A.22
WAUS Data Products Main Line Catalogue 2013
A
Active Components
Ring Redundancy
Ring is the most efcient way to realise redundancy. For
Weidmuller switches any port can be used to build a ring.
The wiring system of the Ring is also like a physical ring,
which can prevent the whole system breaking down along
with one single error. In normal conditions one link of the
Ring doesn't work thus avoiding
loop road.
W-Ring makes the automatic change-over possible in less
than 20 ms and guarantees the reliability of transmission.
Status of the ring can be checked by visiting the Web page
of any switch in the ring. Also you can use the Ring to
achieve the redundancy between the rings by arranging two
links instead
of one.
RSTP Redundancy
Based on IEEE 802.3w, RSTP (Rapid Spanning Tree
Protocol) builds a structure similar to a web and is able
to support more functions by realizing more than one
redundancy. RSTP is an ideal choice for complex network
with unknown linking path. As RSTP must analyse the
whole network when choosing the redundant path, so it
takes more time than ring redundancy. In some big network
systems, the change-over time of RSTP may be as long as
several seconds.
Weidmüller switches support IEEE802.1s Multiple
Spanning Tree Protocol (MSTP). MSTP is backwards
compatible with RSTP and classic STP. MSTP allows
multiple redundant paths and balances the load between
paths for greater efciency.
Ring domain
RSTP domain
RSTP transparent
RSTP transparent
Optimum root by
RSTP
Loop path
W-Ring+
W-Ring
W-Ring
W-Ring
Redundancy in Industrial Ethernet Networks
To keep the industrial automation system running efciently and problem-free, you need an industrial Ethernet system with
high availability and fault-tolerance. Yet almost every device in a network can create errors or stop communication. The
solution is redundancy. Redundancy is a process of adding redundant devices then arranging them according to safety rules.
Extreme industrial environments, such as vibration, temperature difference, or swiching off may easily cause error, especially
in connecting parts like cables and connectors. There are two ways to introduce redundancy into Weidmuller Managed