Chapter Three Operation
Page 25 March 2010
3.3.2 Set WI-MOD-9-E to same network as PC
This is the alternate procedure to setting an IP address in the WI-MOD-9-E. Consult your
network administrator for an IP address on your network, the gateway IP address, and network
mask.
a) Switch Factory Default dip-switch on WI-MOD-9-E to SETUP position.
b) Connect the RS232 port on the WI-MOD-9-E to the RS232 port on the PC using a “straight-
through” serial cable.
c) Open a terminal package (such as Hyperterminal) with 19200bps data rate, 8 data bit, 1 stop,
no parity and no flow control. Make sure that no other programs have control of the serial
port.
d) Power up WI-MOD-9-E. Basic network settings will be displayed on the terminal as
illustrated below. When prompted, hit enter key to stop automatic boot process. You have 5
seconds to abort the boot process.