Pin Signal
1 Neutral / –e
Power supply
2 Live / +e
3 Signal +
Analogue output (optional)
4 Signal –
5 0 V
Pulse output
6 Pulse
7 Reset count Short to 8 to reset count
8 Common
9 Security Short to 8 for setup mode
10 I
nput – / 0 V
I
nputs (according to set-up) in range:
Current: ±24.00 mA
Voltage: ±11.00 V
11 Input +
12 +24 V DC (out)
13 Normally Closed
Alarm one
(optional)
14 Common
15 Normally Open
16 Normally Closed
Alarm two
(optional)
17 Common
18 Normally Open
The PTX800A input circuits are rated category II (suitable for
measurements performed on the low voltage installation). They may
safely be floating with respect to local ground (i.e., subject to common
mode voltages) up to 250 V DC.
Symbols
The instrument labels use symbols in accordance with IEC61010-1:
- Consult documentation; - Direct Current; - Double
Insulated.